Friday, March 22, 2013

Inconsistent gamma values in EULUMDAT (and IES) files.

When we look at the definition of a C-gamma distribution, we can conclude that gamma angle 0° for each C-plane points in the same direction: straight down. Similarly the gamma angle 180° points straight up, for every C-plane. 25721 illum Consequently it should be considered an ERROR in the file when the luminous intensity values for these coincident angles in either cd/klm, candelas, or footcandles are different! Different gamma 0 values Yet there are many files that have this error! What would be the value you use to calculate glare in that direction, or the illuminance? I think these problems result from the measurement protocols, where the anomalies of temperature variation or impact of orientation during measurement is not properly post-processed. In the next release of EulumdatTools these errors are caught, so that they can be manually corrected. Different gamma 0 values problem view

Saturday, January 26, 2013

New version of EulumdatTools 0.9.13.v20130125 released

A new version of EulumdatTools 0.9.13.v20130125 was published on December 21 at http://www.fold1.com/eulumdattools/. Improvements and bug fixes are as follows:
  • Runtime environment is based on Eclipse 3.8.1. Getting ready for 4.x upgrade!
  • Memory usage reduced.
  • Improved license code checks to increase sales.
  • Broken Ant task into separate plugin (for Eclipse IDE only)
  • The version number was updated to 0.9.13.

Registered users should not upgrade using check for upgrades but download a complete new version and register that using their existing license keys. New users can downlaod an apply for 30 day free evaluation license at the installation site

Installation

For use in Eclipse you can use the standard Eclipse update site For stand alone RCP versions of EulumdatTools choose your platform and perform update after installation.: